Model #
FRP15E2Y2R
PTAC unit with Electric Heat, 15,000btu 208/230volt without Seacoast Protection
-
Color: White
- Width: 42"
Height: 16"
Depth: 13-13/16"
Effortless™ Temperature Control
- Frigidaire® air conditioners maintain the preset room temperature so the room remains comfortable at all times, while controling energy usage.
- In the event of a power outage, self-enabling Effortless™ restart feature automatically resumes operating at previous settings when power is restored.
- Simple, intuitive room controls are easy for guests to operate — ensuring a relaxing, more comfortable stay. Features like Effortless™ Auto Restart and Ready-Select® LCD controls reduce maintenance calls.
- Energy Saver Mode can help reduce your utility bills, while still keeping guests cool, by maximizing energy efficiency. In this mode, the unit doesn't run at all times, it turns on and off at different intervals to ensure that the room temperature stays at the set temperature.
- Sound reduction package.
- Offers your guests more cooling flexibility with three adjustable fan settings as well as cool, heat and fan-only options.
- Frigidaire® PTACs are designed to make guest's time away from home even easier. By adding an optional remote thermostat, you can allow guests to effortlessly control their temperature and air movement from anywhere in the room.
- Frigidaire® uses R-410A refrigerant that’s not harmful to the earth’s ozone layer and meets U.S. Environmental Protection Agency requirements.
- With Frigidaire®’s reputation for durability, easy maintenance, availability of reliable parts, and service you can count on, you can be sure that you’re getting the highest-quality performance.
- The upfront location of the filter makes regular cleaning quick and effortless, prolonging the life of the unit.
- Unit operates at a low voltage to protect unoccupied rooms from freezing temperatures.
- Simply select options with the touch of a button.
- Provides nine diagnostic points for self-check and correction of fault conditions.
- Delays restart after a power outage to protect the electrical circuit from power surges.
AC | |
Air Intake | Fresh or Recycled Air |
Fan Speeds - Cool/Fan/Heat | 2003-03-03 |
Cabinet Louvers | No |
Filter Access - Frig | Slide-Out |
Quiet Start-Up | Yes |
24-Hour On/Off Timer | Yes |
Front Desk Control Ready | Yes |
Random Restart Protection | Yes |
Slide-Out Chassis | Yes |
Fan Auto | Yes |
Motor RPM (High/Med/Low) | 1100/1000/920 |
Low Voltage Start-up | Yes |
AC Specifications | |
Room Freeze Protection | Yes |
Noise Level dB (High/Med/Low) | 53/52/51 |
Air Direction Control | Auxiliary 2-Way |
Filter Type | PA/Nylon Mesh |
Charge (ozs) | 38.1 |
Fin Coating | Normal |
Energy Saver | Yes |
Air Volume (CFM) (Max./Med./Min.) | 315/295/275 |
Certifications & Approvals | |
Safety Certification | UL/CUL/CSA |
Controls | |
Control Location | Top Right |
Controls | Electronic |
Dimensions: Cut-Out | |
Height (Min) | 16-5/16" |
Width (Min) | 42-3/16" |
Dimensions: Exterior | |
Depth | 13-13/16" |
Height | 16" |
Width | 42" |
Cabinet Height | 16" |
Cabinet Depth | 13-13/16" |
Electrical Specifications | |
Circuit Breaker | 30A |
Plug Type | LCDI 6-30P |
Voltage Rating | 230V / 208V 60Hz |
Amps (Electrical Heat) | 21.5 / 20.5 |
Watts (Cool) | 1530 / 1510 |
Watts (ElectricalHeat) | 5000 / 4087 |
Power Cord Length | 5-1/2' |
Cable Included | Yes |
Amps (Cool) | 6.7 / 7.5 |
Horsepower (Cool) | 2.05 |
Exterior Dimensions | |
Case Width | 42" |
General Specifications | |
Stack Height | 6 |
Warranty | 2 Year Full/5 Year Sealed System |
Refrigerant | R410a |
Shipping Weight (lbs) | 117 |
Max Wall Thickness | 13-13/16" |
Stuff Quantity | 180 |
Performance | |
BTU (Electrical Heat) | 17000 / 13900 |
Performance Certification | AHRI & CEC |
Energy Efficiency Ratio | 9.8 / 9.7 |
Cool Area (Sq. Ft.) | 875 |
BTU (Cool) | 15000 / 14600 |
Dehumidification (Pints/Hour) | 3.5 |
Extended warranties can save you hundreds, sometimes even thousands of dollars in unexpected repairs. You can contact us, or visit our store for additional details.
Let our team co-ordinate professional delivery and installation on your new purchase. Some restrictions may apply.
Proposition 65 Warning for California Residents
Cancer and Reproductive Harm - P65Warnings.ca.gov
Features
Effortless™ Temperature Control
- Frigidaire® air conditioners maintain the preset room temperature so the room remains comfortable at all times, while controling energy usage.
- In the event of a power outage, self-enabling Effortless™ restart feature automatically resumes operating at previous settings when power is restored.
- Simple, intuitive room controls are easy for guests to operate — ensuring a relaxing, more comfortable stay. Features like Effortless™ Auto Restart and Ready-Select® LCD controls reduce maintenance calls.
- Energy Saver Mode can help reduce your utility bills, while still keeping guests cool, by maximizing energy efficiency. In this mode, the unit doesn't run at all times, it turns on and off at different intervals to ensure that the room temperature stays at the set temperature.
- Sound reduction package.
- Offers your guests more cooling flexibility with three adjustable fan settings as well as cool, heat and fan-only options.
- Frigidaire® PTACs are designed to make guest's time away from home even easier. By adding an optional remote thermostat, you can allow guests to effortlessly control their temperature and air movement from anywhere in the room.
- Frigidaire® uses R-410A refrigerant that’s not harmful to the earth’s ozone layer and meets U.S. Environmental Protection Agency requirements.
- With Frigidaire®’s reputation for durability, easy maintenance, availability of reliable parts, and service you can count on, you can be sure that you’re getting the highest-quality performance.
- The upfront location of the filter makes regular cleaning quick and effortless, prolonging the life of the unit.
- Unit operates at a low voltage to protect unoccupied rooms from freezing temperatures.
- Simply select options with the touch of a button.
- Provides nine diagnostic points for self-check and correction of fault conditions.
- Delays restart after a power outage to protect the electrical circuit from power surges.